81. Blood pressure and its variability: classic and novel measurement techniques.
Schutte AE, Kollias A, Stergiou GS.
+ Εμφάνιση Περίληψης
Current hypertension guidelines recommend using the average values of several blood pressure (BP) readings obtained both in and out of the office for the diagnosis and management of hypertension. In-office BP measurement using an upper-arm cuff constitutes the evidence-based reference method for current BP classification and treatment targets. However, out-of-office BP evaluation using 24 h ambulatory or home BP monitoring is recommended by all major medical associations for obtaining further insights into the BP profile of an individual and how it relates to their daily activities. Importantly, the highly variable nature of office and out-of-office BP readings has been widely acknowledged, including the association of BP variability with cardiovascular outcomes. However, to date, the implications of BP variability on cardiovascular outcomes have largely been ignored, with limited application in clinical practice. Novel cuffless wearable technologies might provide a detailed assessment of the 24 h BP profile and behaviour over weeks or months. These devices offer many advantages for researchers and patients compared with traditional BP monitors, but their accuracy and utility remain uncertain. In this Review, we outline and compare conventional and novel methods and techniques for assessing average BP levels and BP variability, and reflect on the utility and potential of these methods for improving the treatment and management of patients with hypertension.
|
82. Correction to: Comparative effectiveness and safety of non-vitamin K antagonists for atrial fibrillation in clinical practice: GLORIA-AF Registry.
Lip GYH, Kotalczyk A, Teutsch C, Diener HC, Dubner SJ, Halperin JL, Ma CS, Rothman KJ, Marler S, Gurusamy VK, Huisman MV.
|
83. Cuffless Blood Pressure Measurement.
Mukkamala R, Stergiou GS, Avolio AP.
+ Εμφάνιση Περίληψης
Cuffless blood pressure (BP) measurement has become a popular field due to clinical need and technological opportunity. However, no method has been broadly accepted hitherto. The objective of this review is to accelerate progress in the development and application of cuffless BP measurement methods. We begin by describing the principles of conventional BP measurement, outstanding hypertension/hypotension problems that could be addressed with cuffless methods, and recent technological advances, including smartphone proliferation and wearable sensing, that are driving the field. We then present all major cuffless methods under investigation, including their current evidence. Our presentation includes calibrated methods (i.e., pulse transit time, pulse wave analysis, and facial video processing) and uncalibrated methods (i.e., cuffless oscillometry, ultrasound, and volume control). The calibrated methods can offer convenience advantages, whereas the uncalibrated methods do not require periodic cuff device usage or demographic inputs. We conclude by summarizing the field and highlighting potentially useful future research directions.
|
84. Comparative effectiveness and safety of non-vitamin K antagonists for atrial fibrillation in clinical practice: GLORIA-AF Registry.
Lip GYH, Kotalczyk A, Teutsch C, Diener HC, Dubner SJ, Halperin JL, Ma CS, Rothman KJ, Marler S, Gurusamy VK, Huisman MV.
|
85. Evidence on the clinical relevance of short-term blood pressure variability? Untying the Gordian knot.
Kollias A, Kyriakoulis KG, Stergiou GS.
|
86. Quality of Life (QoL) and Outcome After Preservation Rhinoplasty (PR) Using the Rhinoplasty Outcome Evaluation (ROE) Questionnaire-A Prospective Observational Single-Centre Study.
Stergiou G, Schweigler A, Finocchi V, Fortuny CG, Saban Y, Tremp M.
|
87. The effect of S427F mutation on RXRα activity depends on its dimeric partner.
Galdadas I, Bonis V, Vgenopoulou P, Papadourakis M, Kakoulidis P, Stergiou G, Cournia Z, Klinakis A.
+ Εμφάνιση Περίληψης
RXRs are nuclear receptors acting as transcription regulators that control key cellular processes in all tissues. All type II nuclear receptors require RXRs for transcriptional activity by forming heterodimeric complexes. Recent whole-exome sequencing studies have identified the RXRα S427F hotspot mutation in 5% of the bladder cancer patients, which is always located at the interface of RXRα with its obligatory dimerization partners. Here, we show that mutation of S427 deregulates transcriptional activity of RXRα dimers, albeit with diverse allosteric mechanisms of action depending on its dimeric partner. S427F acts by allosteric mechanisms, which range from inducing the collapse of the binding pocket to allosteric stabilization of active co-activator competent RXRα states. Unexpectedly, RXR S427F heterodimerization leads to either loss- or gain-of-function complexes, in both cases likely compromising its tumor suppressor activity. This is the first report of a cancer-associated single amino acid substitution that affects the function of the mutant protein variably depending on its dimerization partner.
|
88. Validation of the InBody BPBIO210 manual auscultatory hybrid device for professional office use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
Ntineri A, Menti A, Kyriakoulis KG, Bountzona I, Prapa S, Kollias A, Stergiou GS.
|
89. Blood pressure variability assessed by office, home, and ambulatory measurements: comparison, agreement, and determinants.
Boubouchairopoulou N, Ntineri A, Kollias A, Destounis A, Stergiou GS.
+ Εμφάνιση Περίληψης
The present study compared the blood pressure variability (BPV) among office (OBP), home (HBP), and ambulatory blood pressure (ABP) measurements and assessed their determinants, as well as their agreement in identifying individuals with high BPV. Individuals attending a hypertension clinic had OBP measurements (2-3 visits) and underwent HBP monitoring (3-7 days, duplicate morning and evening measurements) and ABP monitoring (24 h, 20-min intervals). BPV was quantified using the standard deviation (SD), coefficient of variation (CV), and variability independent of the mean (VIM) using all BP readings obtained by each method. A total of 626 participants were analyzed (age 52.8 ± 12.0 years, 57.7% males, 33.1% treated). Systolic BPV was usually higher than diastolic BPV, and out-of-office BPV was higher than office BPV, with ambulatory BPV giving the highest values. BPV was higher in women than men, yet it was not different between untreated and treated individuals. Associations among BPV indices assessed using different measurement methods were weak (r 0.1-0.3) but were stronger between out-of-office BPV indices. The agreement between methods in detecting individuals with high BPV was low (30-40%) but was higher between out-of-office BPV indices. Older age was an independent determinant of increased OBP variability. Older age, female sex, smoking, and overweight/obesity were determinants of increased out-of-office BPV. These data suggest that BPV differs with different BP measurement methods, reflecting different pathophysiological phenomena, whereas the selection of the BPV index is less important. Office and out-of-office BP measurements appear to be complementary methods in assessing BPV.
|
90. Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.
Mukkamala R, Yavarimanesh M, Natarajan K, Hahn JO, Kyriakoulis KG, Avolio AP, Stergiou GS.
+ Εμφάνιση Περίληψης
Several novel cuffless wearable devices and smartphone applications claiming that they can measure blood pressure (BP) are appearing on the market. These technologies are very attractive and promising, with increasing interest among health care professionals for their potential use. Moreover, they are becoming popular among patients with hypertension and healthy people. However, at the present time, there are serious issues about BP measurement accuracy of cuffless devices and the 2021 European Society of Hypertension Guidelines on BP measurement do not recommend them for clinical use. Cuffless devices have special validation issues, which have been recently recognized. It is important to note that the 2018 Universal Standard for the validation of automated BP measurement devices developed by the American Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization is inappropriate for the validation of cuffless devices. Unfortunately, there is an increasing number of publications presenting data on the accuracy of novel cuffless BP measurement devices, with inadequate methodology and potentially misleading conclusions. The objective of this review is to facilitate understanding of the capabilities and limitations of emerging cuffless BP measurement devices. First, the potential and the types of these devices are described. Then, the unique challenges in evaluating the BP measurement accuracy of cuffless devices are explained. Studies from the literature and computer simulations are employed to illustrate these challenges. Finally, proposals are given on how to evaluate cuffless devices including presenting and interpreting relevant study results.
|
91. Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants.
|
92. Home blood pressure monitoring: methodology, clinical relevance and practical application: a 2021 position paper by the Working Group on Blood Pressure Monitoring and Cardiovascular Variability of the European Society of Hypertension.
Parati G, Stergiou GS, Bilo G, Kollias A, Pengo M, Ochoa JE, Agarwal R, Asayama K, Asmar R, Burnier M, De La Sierra A, Giannattasio C, Gosse P, Head G, Hoshide S, Imai Y, Kario K, Li Y, Manios E, Mant J, McManus RJ, Mengden T, Mihailidou AS, Muntner P, Myers M, Niiranen T, Ntineri A, O'Brien E, Octavio JA, Ohkubo T, Omboni S, Padfield P, Palatini P, Pellegrini D, Postel-Vinay N, Ramirez AJ, Sharman JE, Shennan A, Silva E, Topouchian J, Torlasco C, Wang JG, Weber MA, Whelton PK, White WB, Mancia G.
+ Εμφάνιση Περίληψης
The present paper provides an update of previous recommendations on Home Blood Pressure Monitoring from the European Society of Hypertension (ESH) Working Group on Blood Pressure Monitoring and Cardiovascular Variability sequentially published in years 2000, 2008 and 2010. This update has taken into account new evidence in this field, including a recent statement by the American Heart association, as well as technological developments, which have occurred over the past 20 years. The present document has been developed by the same ESH Working Group with inputs from an international team of experts, and has been endorsed by the ESH.
|
93. A multivariate analysis after preservation rhinoplasty (PR) - a prospective study.
Stergiou G, Fortuny CG, Schweigler A, Finocchi V, Saban Y, Tremp M.
|
94. Statin use and mortality in COVID-19 patients: Updated systematic review and meta-analysis.
Kollias A, Kyriakoulis KG, Kyriakoulis IG, Nitsotolis T, Poulakou G, Stergiou GS, Syrigos K.
|
95. Isolated diastolic vs. systolic hypertension phenotypes and outcomes: prospective cohort of newly diagnosed individuals with hypertension.
Thomopoulos C, Andrikou I, Konstantinidis D, Iliakis P, Kalos T, Polyzos D, Drogkaris S, Siafi E, Tousoulis D, Stergiou GS, Tsioufis C.
|
96. Opportunistic screening for hypertension in the general population in Greece: International Society of Hypertension May Measurement Month 2019.
Stergiou GS, Menti A, Doumas M, Gkaliagkousi E, Grassos C, Kalaitzidis RG, Kallistratos MS, Katsi V, Krokidis X, Makris T, Manios E, Manolis A, Marketou M, Papadakis JA, Papadopoulos D, Protogerou A, Chatzopoulos M, Sarafidis P, Tsioufis C, Zebekakis P.
+ Εμφάνιση Περίληψης
Hypertension remains a major public health issue with inadequate control worldwide. The May Measurement Month (MMM) initiative by the International Society of Hypertension was implemented in Greece in 2019 aiming to raise hypertension awareness and control. Adult volunteers (≥18 years) were recruited through opportunistic screening in five urban areas. Information on medical history and triplicate sitting blood pressure (BP) measurements were obtained using validated automated upper-arm devices. Hypertension was defined as systolic BP ≥140 mmHg and/or diastolic ≥90 mmHg, and/or self-reported use of drugs for hypertension. A total of 5727 were analysed [mean age 52.7 (SD 16.6) years, men 46.5%, 88.3% had BP measurement in the last 18 months]. The prevalence of hypertension was (41.6%) and was higher in men and in older individuals. Among individuals with hypertension, 78.7% were diagnosed, 73.1% treated, and 48.3% controlled. Awareness, treatment, and control of hypertension were higher in women and in older individuals. Hypertensives had a higher body mass index (BMI) and were more likely to have diabetes, myocardial infarction and stroke, and less likely to smoke than normotensives (all
|
97. May Measurement Month 2019: results of blood pressure screening from 47 countries.
Poulter NR, Borghi C, Damasceno A, Jafar TH, Khan N, Kokubo Y, Nilsson PM, Prabhakaran D, Schlaich MP, Schutte AE, Stergiou GS, Unger T, Beaney T.
|
98. 'Apples to oranges' and 'Less is more'.
Argyris AA, Samara S, Blacher J, Papaioannou TG, Stergiou GS, Vlachopoulos C, Wassertheurer S, Weber T, Protogerou AD.
|
99. Joint ESH excellence centers' national meeting on renal sympathetic denervation: A Greek experts' survey.
Doumas M, Andreadis E, Andronoglou M, Davlouros P, Dimitriadis K, Gkaliagkousi E, Grassos H, Hatzitolios A, Iliakis P, Kalaitzidis R, Kallistratos E, Kasiakogias A, Konstantinidis D, Kotsis V, Makris T, Manolis A, Moulias A, Marketou M, Papadakis I, Papadopoulos D, Poulimenos L, Sanidas E, Sarafidis P, Savopoulos C, Stergiou G, Tatakis F, Thomopoulos K, Triantafyllidi H, Triantafyllou A, Vlachakos D, Zebekakis P, Ziakas A, Papademetriou V, Tsioufis C.
|
100. Nighttime Home Blood Pressure in Children: Association with Ambulatory Blood Pressure and Preclinical Organ Damage.
Stambolliu E, Kollias A, Bountzona I, Ntineri A, Servos G, Vazeou A, Stergiou GS.
+ Εμφάνιση Περίληψης
|