121. Use of Static Cutoffs of Hypertension to Determine High cIMT in Children and Adolescents: An International Collaboration Study.
Yang L, Whincup PH, López-Bermejo A, Caserta CA, Muniz Medeiros CC, Kollias A, Pacifico L, Reinehr T, Litwin M, Owen CG, Bassols J, Romeo EL, Almeida Ramos TD, Stergiou GS, Zhao M, Yang L, Xargay-Torrent S, Amante A, Gusmão TME, Grammatikos E, Wang M, Prats-Puig A, Franklin de Carvalho D, Carreras-Badosa G, de Oliveira Simões M, Mas-Pares B, Shui W, Deanfield JE, Magnussen CG, Xi B.
|
122. May Measurement Month 2019: The Global Blood Pressure Screening Campaign of the International Society of Hypertension.
Beaney T, Schutte AE, Stergiou GS, Borghi C, Burger D, Charchar F, Cro S, Diaz A, Damasceno A, Espeche W, Jose AP, Khan N, Kokubo Y, Maheshwari A, Marin MJ, More A, Neupane D, Nilsson P, Patil M, Prabhakaran D, Ramirez A, Rodriguez P, Schlaich M, Steckelings UM, Tomaszewski M, Unger T, Wainford R, Wang J, Williams B, Poulter NR.
+ View Abstract
Elevated blood pressure remains the single biggest risk factor contributing to the global burden of disease and mortality. May Measurement Month is an annual global screening campaign aiming to improve awareness of blood pressure at the individual and population level. Adults (≥18 years) recruited through opportunistic sampling were screened at sites in 92 countries during May 2019. Ideally, 3 blood pressure readings were measured for each participant, and data on lifestyle factors and comorbidities were collected. Hypertension was defined as a systolic blood pressure ≥140 mm Hg, or a diastolic blood pressure ≥90 mm Hg (mean of the second and third readings) or taking antihypertensive medication. When necessary, multiple imputation was used to estimate participants' mean blood pressure. Mixed-effects models were used to evaluate associations between blood pressure and participant characteristics. Of 1 508 130 screenees 482 273 (32.0%) had never had a blood pressure measurement before and 513 337 (34.0%) had hypertension, of whom 58.7% were aware, and 54.7% were on antihypertensive medication. Of those on medication, 57.8% were controlled to <140/90 mm Hg, and 28.9% to <130/80 mm Hg. Of all those with hypertension, 31.7% were controlled to <140/90 mm Hg, and 350 825 (23.3%) participants had untreated or inadequately treated hypertension. Of those taking antihypertensive medication, half were taking only a single drug, and 25% reported using aspirin inappropriately. This survey is the largest ever synchronized and standardized contemporary compilation of global blood pressure data. This campaign is needed as a temporary substitute for systematic blood pressure screening in many countries worldwide.
|
123. Home and ambulatory blood pressure monitoring in children, adolescents and young adults: comparison, diagnostic agreement and association with preclinical organ damage.
Zeniodi ME, Ntineri A, Kollias A, Servos G, Moyssakis I, Destounis A, Harokopakis A, Vazeou A, Stergiou GS.
|
124. 2020 International Society of Hypertension global hypertension practice guidelines.
Unger T, Borghi C, Charchar F, Khan NA, Poulter NR, Prabhakaran D, Ramirez A, Schlaich M, Stergiou GS, Tomaszewski M, Wainford RD, Williams B, Schutte AE.
|
125. 2020 International Society of Hypertension Global Hypertension Practice Guidelines.
Unger T, Borghi C, Charchar F, Khan NA, Poulter NR, Prabhakaran D, Ramirez A, Schlaich M, Stergiou GS, Tomaszewski M, Wainford RD, Williams B, Schutte AE.
|
126. Blood pressure target for hypertension in chronic kidney disease: One size does not fit all.
Kollias A, Kyriakoulis KG, Stergiou GS.
+ View Abstract
There is disagreement between the American and the European guidelines for hypertension management in regard to the optimal blood pressure target in patients with chronic kidney disease (CKD). Randomized clinical trials and meta-analyses of individual patient data pooled from these trials do not clearly support an intensive blood pressure target for the entire population of CKD patients with hypertension. However, some evidence suggests that in CKD patients with proteinuria strict blood pressure control might confer benefit in terms of renal outcome. Tailored treatment strategy based on the individual's proteinuric profile and tolerability along with standardization of blood pressure measurement methodology including out-of-office evaluation are of paramount importance in patients with CKD.
|
127. Thromboembolic risk and anticoagulant therapy in COVID-19 patients: emerging evidence and call for action.
Kollias A, Kyriakoulis KG, Dimakakos E, Poulakou G, Stergiou GS, Syrigos K.
+ View Abstract
Emerging evidence shows that severe coronavirus disease 2019 (COVID-19) can be complicated with coagulopathy, namely disseminated intravascular coagulation, which has a rather prothrombotic character with high risk of venous thromboembolism. The incidence of venous thromboembolism among COVID-19 patients in intensive care units appears to be somewhat higher compared to that reported in other studies including such patients with other disease conditions. D-dimer might help in early recognition of these high-risk patients and also predict outcome. Preliminary data show that in patients with severe COVID-19, anticoagulant therapy appears to be associated with lower mortality in the subpopulation meeting sepsis-induced coagulopathy criteria or with markedly elevated d-dimer. Recent recommendations suggest that all hospitalized COVID-19 patients should receive thromboprophylaxis, or full therapeutic-intensity anticoagulation if such an indication is present.
|
128. Seasonal Blood Pressure Variation: A Neglected Confounder in Clinical Hypertension Research and Practice.
Stergiou GS, Palatini P, Kollias A, Kyriakoulis KG, Myers M, O'Brien E, Parati G, Modesti PA.
|
129. The European/International Fibromuscular Dysplasia Registry and Initiative (FEIRI)-clinical phenotypes and their predictors based on a cohort of 1000 patients.
Pappaccogli M, Di Monaco S, Warchoł-Celińska E, Lorthioir A, Amar L, Aparicio LS, Beauloye C, Bruno RM, Chenu P, de Leeuw P, De Backer T, Delmotte P, Dika Z, Gordin D, Heuten H, Iwashima Y, Krzesinski JM, Kroon AA, Mazzolai L, Poch E, Sarafidis P, Seinturier C, Spiering W, Toubiana L, Van der Niepen P, van Twist D, Visonà A, Wautrecht JC, Witowicz H, Xu J, Prejbisz A, Januszewicz A, Azizi M, Persu A.
|
130. Nonvalidated Home Blood Pressure Devices Dominate the Online Marketplace in Australia: Major Implications for Cardiovascular Risk Management.
Picone DS, Deshpande RA, Schultz MG, Fonseca R, Campbell NRC, Delles C, Hecht Olsen M, Schutte AE, Stergiou G, Padwal R, Zhang XH, Sharman JE.
+ View Abstract
Self-home blood pressure (BP) monitoring is recommended to guide clinical decisions on hypertension and is used worldwide for cardiovascular risk management. People usually make their own decisions when purchasing BP devices, which can be made online. If patients purchase nonvalidated devices (those not proven accurate according to internationally accepted standards), hypertension management may be based on inaccurate readings resulting in under- or over-diagnosis or treatment. This study aimed to evaluate the number, type, percentage validated, and cost of home BP devices available online. A search of online businesses selling devices for home BP monitoring was conducted. Multinational companies make worldwide deliveries, so searches were restricted to BP devices available for one nation (Australia) as an example of device availability through the global online marketplace. Validation status of BP devices was determined according to established protocols. Fifty nine online businesses, selling 972 unique BP devices were identified. These included 278 upper-arm cuff devices (18.3% validated), 162 wrist-cuff devices (8.0% validated), and 532 wrist-band wearables (0% validated). Most BP devices (92.4%) were stocked by international e-commerce businesses (eg, eBay, Amazon), but only 5.5% were validated. Validated cuff BP devices were more expensive than nonvalidated devices: median (interquartile range) of 101.1 (75.0-151.5) versus 67.4 (30.4-112.8) Australian Dollars. Nonvalidated BP devices dominate the online marketplace and are sold at lower cost than validated ones, which is a major barrier to accurate home BP monitoring and cardiovascular risk management. Before purchasing a BP device, people should check it has been validated at https://www.stridebp.org.
|
131. Cardiovascular risk factors in HIV infected individuals: Comparison with general adult control population in Greece.
Touloumi G, Kalpourtzi N, Papastamopoulos V, Paparizos V, Adamis G, Antoniadou A, Chini M, Karakosta A, Makrilakis K, Gavana M, Vantarakis A, Psichogiou M, Metallidis S, Sipsas NV, Sambatakou H, Hadjichristodoulou C, Voulgari PV, Chrysos G, Gogos C, Chlouverakis G, Tripsianis G, Alamanos Y, Stergiou G.
|
132. Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability.
Palatini P, Asmar R, O'Brien E, Padwal R, Parati G, Sarkis J, Stergiou G.
+ View Abstract
: Blood pressure measurement in obese individuals can be challenging because of the difficulty in properly cuffing large upper arms. Achieving a proper cuff fit can be problematic especially in people with a shorter arm length relative to circumference. This expert statement provides recommendations on blood pressure measurement in large arms for clinical use and research purposes. Tronco-conically shaped cuffs should be used in people with large arms, especially with arm circumferences greater than 42 cm as they better fit on the conical arm shape. Cuffs with frustum of the cone slant angle of 85° should satisfy most conditions. In individuals with short upper-arm that does not allow application of a properly sized cuff, wrist or forearm measurement might be used in clinical practice, but not for validation of automatic devices. Wide-range cuffs coupled to oscillometric devices provided with special software algorithms can also be used as alternatives to standard cuff measurement, provided they are independently validated per AAMI/ISO 81060-2 protocol. For validation studies, the intraarterial measurement is generally considered as the gold standard, yet for possible methodological pitfalls and ethical concerns, it is not recommended as the method of choice. Tronco-conical cuffs with inflatable bladder dimensions of 37-50 × 75-100% arm circumference should be used for reference auscultatory blood pressure measurement wherever the upper arm length allows a proper fit. There is a need for future studies that help identify the optimal shape of cuffs and bladders investigating the influence of sex, age, arm physical properties, and artery characteristics.
|
133. Reply.
Sharman JE, O'Brien E, Alpert B, Delles C, Hecht Olsen M, McManus RJ, Padwal R, Parati G, Stergiou G.
|
134. [Lancet Commission on Hypertension Group position statement on the global improvement of accuracy standards for devices that measure blood pressurePosicionamento do Grupo da
Sharman JE, O'Brien E, Alpert B, Schutte AE, Delles C, Olsen MH, Asmar R, Atkins N, Barbosa E, Calhoun D, Campbell NRC, Chalmers J, Benjamin I, Jennings G, Laurent S, Boutouyrie P, Lopez-Jaramillo P, McManus RJ, Mihailidou AS, Ordunez P, Padwal R, Palatini P, Parati G, Poulter N, Rakotz MK, Rosendorff C, Saladini F, Scuteri A, Barroso WS, Cho MC, Sung KC, Townsend RR, Wang JG, Hansen TW, Wozniak G, Stergiou G.
+ View Abstract
The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3 000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organization for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP.
|
135. Seasonal blood pressure variation assessed by different measurement methods: systematic review and meta-analysis.
Kollias A, Kyriakoulis KG, Stambolliu E, Ntineri A, Anagnostopoulos I, Stergiou GS.
|
136. Seasonal variation in blood pressure: Evidence, consensus and recommendations for clinical practice. Consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability.
Stergiou GS, Palatini P, Modesti PA, Asayama K, Asmar R, Bilo G, de la Sierra A, Dolan E, Head G, Kario K, Kollias A, Manios E, Mihailidou AS, Myers M, Niiranen T, Ohkubo T, Protogerou A, Wang J, O'Brien E, Parati G.
+ View Abstract
: Blood pressure (BP) exhibits seasonal variation with lower levels at higher environmental temperatures and higher at lower temperatures. This is a global phenomenon affecting both sexes, all age groups, normotensive individuals, and hypertensive patients. In treated hypertensive patients it may result in excessive BP decline in summer, or rise in winter, possibly deserving treatment modification. This Consensus Statement by the European Society of Hypertension Working Group on BP Monitoring and Cardiovascular Variability provides a review of the evidence on the seasonal BP variation regarding its epidemiology, pathophysiology, relevance, magnitude, and the findings using different measurement methods. Consensus recommendations are provided for health professionals on how to evaluate the seasonal BP changes in treated hypertensive patients and when treatment modification might be justified. (i) In treated hypertensive patients symptoms appearing with temperature rise and suggesting overtreatment must be investigated for possible excessive BP drop due to seasonal variation. On the other hand, a BP rise during cold weather, might be due to seasonal variation. (ii) The seasonal BP changes should be confirmed by repeated office measurements; preferably with home or ambulatory BP monitoring. Other reasons for BP change must be excluded. (iii) Similar issues might appear in people traveling from cold to hot places, or the reverse. (iv) BP levels below the recommended treatment goal should be considered for possible down-titration, particularly if there are symptoms suggesting overtreatment. SBP less than 110 mmHg requires consideration for treatment down-titration, even in asymptomatic patients. Further research is needed on the optimal management of the seasonal BP changes.
|
137. Prognostic Relevance of Short-Term Blood Pressure Variability: The Spanish ABPM Registry.
de la Sierra A, Banegas JR, Bursztyn M, Parati G, Stergiou G, Mateu A, Vinyoles E, Segura J, Gorostidi M, Ruilope LM.
+ View Abstract
The prognostic relevance of short-term blood pressure (BP) variability in hypertension is not clearly established. We aimed to evaluate the association of short-term BP variability, assessed through ambulatory BP monitoring, with total and cardiovascular mortality in a large cohort of patients with hypertension. We selected 63 910 subjects from the Spanish ABPM Registry from 2004 to 2014, with a median follow-up of 4.7 years. Systolic and diastolic BP SD from 24 hours, daytime, and nighttime, weighted SD (mean of daytime and nighttime SD weighted for period duration), average real variability (mean of differences between consecutive readings), variation independent of the mean, and BP variability ratio (ratio between systolic and diastolic 24-hour SD) were calculated through 24-hour ambulatory BP monitoring performed at baseline. Association with total and cardiovascular mortality (obtained through death certificates) were assessed by Cox regression models adjusted for clinical confounders and BP. Patients who died during follow-up had higher values of BP variability compared with those remaining alive. In fully adjusted models, daytime, nighttime, and weighted SD, systolic and diastolic, as well as diastolic average real variability, were all significantly associated with total and cardiovascular mortality. Hazard ratios for 1 SD increase ranged from 1.05 to 1.09 for total mortality and from 1.07 to 1.12 for cardiovascular mortality. A nighttime systolic SD ≥12 mm Hg was independently associated with total (hazard ratio: 1.13 [95% CI, 1.06-1.21]) and cardiovascular mortality (hazard ratio: 1.21 [95% CI, 1.09-1.36]). We conclude that short-term BP variability is independently associated with total and cardiovascular mortality in patients with hypertension.
|
138. Validation of the InBody BPBIO250 oscillometric blood pressure monitor for professional office use in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
Kollias A, Gravvani A, Anagnostopoulos I, Kyriakoulis KG, Bountzona I, Menti A, Stergiou GS.
|
139. Lancet Commission on Hypertension group position statement on the global improvement of accuracy standards for devices that measure blood pressure.
Sharman JE, O'Brien E, Alpert B, Schutte AE, Delles C, Hecht Olsen M, Asmar R, Atkins N, Barbosa E, Calhoun D, Campbell NRC, Chalmers J, Benjamin I, Jennings G, Laurent S, Boutouyrie P, Lopez-Jaramillo P, McManus RJ, Mihailidou AS, Ordunez P, Padwal R, Palatini P, Parati G, Poulter N, Rakotz MK, Rosendorff C, Saladini F, Scuteri A, Sebba Barroso W, Cho MC, Sung KC, Townsend RR, Wang JG, Willum Hansen T, Wozniak G, Stergiou G.
+ View Abstract
: The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organisation for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP.
|
140. Metabolic syndrome, clustering of cardiovascular risk factors and high carotid intima-media thickness in children and adolescents.
Zhao M, Caserta CA, Medeiros CCM, López-Bermejo A, Kollias A, Zhang Q, Pacifico L, Reinehr T, Litwin M, Bassols J, Romeo EL, Ramos TDA, Stergiou GS, Yang L, Xargay-Torrent S, Amante A, Estrela TM, Grammatikos E, Zhang Y, Prats-Puig A, Franklin de Carvalho D, Yang L, Carreras-Badosa G, de Oliveira Simões M, Hou Y, Lizarraga-Mollinedo E, Shui W, Guo T, Wang M, Zhang Y, Bovet P, Xi B.
|